Check the voltage across the WHT and GRN terminals on the master cable terminal block. DIY Installations, Automated Gate Systems for For Multi-Family Properties, An Automated Driveway Gate from GateCrafters.com, Designing an Automated Gate for Easy Access, Automated Sliding Gates for Entrance and Exit, Automated Sliding Gates for DIY Homeowners, Automatic Gate Systems can be Installed by Anybody, Automatic Gates At Budget-Friendly Prices, Wrought Iron Gates - A Stylish Home Addition, Electric Driveway Gates are Easy to Operate, A GTO Gate Opener Selection from GateCrafters.com, Mule Gate Opener Products at Affordable Prices, Why an Electric Gate is Good for your Home, An Electric Sliding Gate for Homes Across the USA, Electric Swinging Gate Options from GateCrafters.com, A Swing Gate Opener from GateCrafters.com, Wrought Iron Gates look from GateCrafters.com, Swing Gate Opener Products from Reputable Brands. Check your power source. A recent power outage or surge could have damage the electrical circuits, causing the door opener to behave in an erratic manner. You should have 12 VDC. If the push/pull tube on the operator arm is all the way in, touch the black wire from the motor to the positive battery post and the red wire to the negative battery post. The Mighty Mule brand includes automatic and smart gate openers and garage door openers, which are reasonably priced as compared to other brands. Check the fuses. You should have about 12 VDC. Press the button on the opener remote to open the gate. If you have a swing gate operator or slide gate electric opener the reasons are usually the same. Powered by lithium batteries. Watch the gate and be ready to stop it with the remote, push-button, or keypad when it gets to the open position. Once the gate is in the ideal open position, go to the control board and hold down the Set Limit button for 5 seconds or until it beeps. Replace the batteries in your remote transmitter, as worn-out batteries can send random signals. First, check the circuit board to make sure there is no problem with the board. Worlds Largest Online DIY Gate Opener Retailer • Unbeatable Technical Support • Try these troubleshooting instructions of your Mighty Mule gate opener battery is not charging: The Indoor Haven is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com. The arm should start retracting. Master gate opens slightly and the slave gate will close. To troubleshoot: If the auto-close timer is not automatically closing the gate for MM360, try the following: If the gate opener senses an obstruction at the end of the open cycle, it will prevent the gate from automatically closing. If all your power sources check out test your battery. We have a Mighty Mule 502 gate opener for the front gate. GTO gate opener troubleshooting is often performed by homeowners as some of the problems are really simple. Get free shipping on qualified Mighty Mule Gate Opener products or Buy Online Pick Up in Store today. Keep the transformer disconnected from the circuit board. The Mighty Mule Gate Opener utilizes Type A, an inherent (i.e., built-in) entrapment sensing system as the primary type of entrapment protection. The Mighty Mule Smart Control App allows you to monitor and control your Mighty Mule Smart Control Door/Gate Openers from the convenience of your mobile device, from anywhere in the world. Press and release the transmitter to close the gate for normal operation. Also, the Mighty Mule Gate Opener has provisions for the connection of Type B2 protection to be used as the secondary type of entrapment protection, if desired. Disconnect the slave arm from the slave cable terminals and wire it to the master cable terminals. Press the keypad, remote, or push the button and make sure the gate closes to the fully closed position. Press and hold the “LEARN MAST LIMIT” button for 10 seconds, or until the alarm sounds to clear. Make sure the control box is in the OFF position. 12 VDC or lower is too low and can cause erratic intermittent operations. Another could be your battery is not getting electricity to charge it. Locate the ON/OFF switch on the bottom of the control box and turn it to the OFF position. GTO Mighty Mule. It can also cause intermittent operations. It’s been up there 4 or 5 years, and it’s worked well. Remove the pin lock from the front mount with the key that came with it. If you programmed the right button on the dual remote to open the gate, then set the first eight dip switches in the single button remote exactly the same as the eight dip switches in the dual remote. If the master arm operates properly without the slave arm connected, you probably have a bad limit switch or power cable on the slave arm. Free shipping. You get home one day and when the arm is fully retracted, it stops and starts beeping. Check for damage in the electrical circuits responsible for opening and closing your garage door. Under normal conditions, it may be noted that the operator arms for the MM560/562 take longer to open than the MM1000 or PRO 1000. If it does, be careful not to allow it retract over half way as it could damage the limit switches in the arm. New Listing Mighty Mule Replacement Control Board Mighty Mule Gate Openers (R4211) UNTESTED. The installation can come in two forms. Check across the BLU and GRN terminals on the master terminal block. You can verify this by trying to operate the slave arm connected to the master cable terminals. To troubleshoot, try these instructions: If you hear three beeps with two seconds off repeatedly and the gate opener will not work, then you are experiencing a master arm rev counter error. Press the button on the remote to close the gate. If you do not get the proper voltage at the circuit board with the BLU and WHT wires disconnected, you may need to replace the circuit board. To troubleshoot: Mighty Mule Gate Opener Randomly Opens and Closes on its Own. Re: Mighty Mule Gate Opener ... Continous beep could be a couple things. The Mighty Mule Smart Control App notifies you of who operated your Smart Door/Gate and Door light and when, tracking Control door/gate … Remove the hairpin clip, clevis pin, and bushing from either the front or rear mounting point. You will need to have it repaired. If you hear 1 beep with 2 seconds off repeatedly and slave arm will not work connected to the master cable terminal, then the circuit board is telling you that it cannot read the limit switch inside the slave arm. If the push/pull tube on the operator arm is all the way out, touch the black wire from the motor to the negative battery post and red wire from the motor to the positive battery post. If you have the arm wired to the master cable terminal block, the connections are good, and the cable has not been damaged, there is a problem with the circuit board or the operator arm. If you get proper voltages and you hear the motor attempt to run upon activation, the problem may be the revolution counter inside the arm. The Mighty Mule Gate Operator features Dual Sense Technology™. Easy to install Mighty Mule Gates, Gate Openers and … Technical Support. Check for debris and obstructions that could be causing your gate opener to randomly open and close. Disconnect the slave arm from the slave cable terminals. If the arm works, you may have a problem with the slave arm. When I push the button to close the gates to set the limit the master gate trys to open more and stops and the slave gate will close all the way. Compatible with 318 mz code-safe and dip-switch receivers. I had the same problem with my 2014 RS5. Time left 4d 18h left. The voltage should not drop more than 1vdc. Disconnect the transformer from the power input terminal block and check the voltage across the wires. Our complete line of Mighty Mule electric driveway gate openers and smart garage door openers offer the perfect way to add security and convenience to your home or business. Make sure that the wires are on the correct terminals and making good contact. Hold down the Set Limit button on the control board for 10 seconds. Built in visor clip and transmitting indication light. Continue to hold the remote transmitter button until the alarm sounds. The Mighty Mule Gate Operator also has an adjustable auto-close feature. Make sure there is no corrosion around the battery posts and that the connections are tightly secured. A beeping Mighty Mule gate opener could mean there is a problem or an error. If you have already programmed a single button remote and the ninth dip switch is set to a (-), then use the dual button remote and begin programming following the instructions beginning at the first step. Mighty Mule Gate Opener Troubleshooting 3 Beeps If you hear 3 beeps with 2 seconds, then pause and repeats this indicates a master arm rev counter error. 1 beep every 2 seconds: Master Arm limit switch. Remove the back cover of the transmitter. Make sure that the wires are on the correct terminals and making good contact. Look through the plastic at the wire that connects the two metal posts together. Turn the #1 dip switch in the block of seven switches to the off position to disable soft start/stop. If the battery is lower than 12vdc, it can make the motor run slow and even cause the circuit board to sense obstructions. To remove the arm from a gate that does not have pin locks, follow these instructions: If you have pin locks, follow these instructions: If your gate opener seems to be operating slowly, it could be because of the following possible reasons: If you hear 3 beeps with 2 seconds, then pause and repeats this indicates a master arm rev counter error. Your battery in your GTO, inc / Mighty Mule automatic driveway gate opener is running low. We are compensated for referring traffic and business to these companies. Especially check the GRN, WHT, and BLU wires. If you do not have the automatic gate lock or a stop plate that requires the slave gate to close first, you can gain a couple of seconds by switching the #4 dip switch for Simultaneous Open. Press and hold the transmitter button while sliding the ON/OFF switch to the ON position. Turn the power OFF and back ON to reset the circuit board. If you have between 10-13 VDC across both the terminals, the problem is with the operator arm and the circuit board is good. You should have about 12 VDC. Gate Openers Driveway Gates Garage Door Openers. Make sure all the transmitters you use to open and close the garage door are working properly. You should have 12 VDC. Mighty Mule 362-D Installation Instructions . This equipment is similar to other gate or door and/or user agree to assume responsibility for all equipment and meets or exceeds Underwriters liability and use of this … Press and hold one of the remote transmitter buttons while turning the ON/OFF switch to the ON position. Check across the BLU and GRN terminals on the slave cable terminal block. In this guide, we take you through the troubleshooting steps for resolving the common issues with these gate openers. If you do not hear the motor attempt to run upon activation, the problem could be with the motor or the connections on the wires to the motor. Replacement Automatic Gate Opener arm for the Mighty Mule FM600 and MM660 Price: $278.00 (1) Replacement Control Board for Automatic Gate Operators Part# R4211 Replacement board for the Mighty Mule FM500/502 and MM560/562.